×

:

Not a valid Time
This is a required field.
Vernier - Go Direct® O2 Gas Sensor

Vernier - Go Direct® O2 Gas Sensor

Vernier - Go Direct® Weather System - Go Direct Weather (sensor only)

Vernier - Go Direct® Weather System - Go Direct Weather (sensor only)

Vernier - Go Direct® Optical Dissolved Oxygen Probe

£580.27 £483.56

The Go Direct Optical Dissolved Oxygen Probe combines the power of multiple sensors to measure dissolved oxygen, water temperature, and atmospheric pressure. Ideal for experiments in biology, ecology, and environmental science courses, the Go Direct Optical Dissolved Oxygen Probe uses luminescent technology to provide fast, easy, and accurate results. Perfect for the field or for the laboratory,…

SKU
VER-GDX-ODO

The Go Direct Optical Dissolved Oxygen Probe combines the power of multiple sensors to measure dissolved oxygen, water temperature, and atmospheric pressure. Ideal for experiments in biology, ecology, and environmental science courses, the Go Direct Optical Dissolved Oxygen Probe uses luminescent technology to provide fast, easy, and accurate results. Perfect for the field or for the laboratory, this probe requires no calibration, no filling solution, no warm-up time, and no stirring.

This waterproof probe is ready to sample dissolved oxygen immediately without additional setup or the need to warm it up—so more class time can be spent on the investigation.

The Go Direct Optical Dissolved Oxygen Probe can be used in a variety of experiments:

  • Investigate the relationship between temperature and dissolved oxygen in water.
  • Measure primary productivity or biological/biochemical oxygen demand.
  • Explore the interdependence of plants and animals.
  • Monitor watersheds over time.

Rechargeable Battery—Ready When You Are

The robust rechargeable battery offers long battery life and provides always-ready operation when using the sensor wirelessly. Monitor battery life directly from our award-winning Vernier Graphical Analysis® app, as well as LabQuest® 3. Should the battery run low, simply connect the sensor to the charging cable and keep on collecting—no interruptions or inconvenience to you or your students.

Wireless or Wired—The Flexibility to Choose

Our Go Direct sensors connect directly to your mobile device, Chromebook™, or computer using our Vernier Graphical Analysis® app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the best solution for your classroom or laboratory.

Biology and Environmental Science Essentials: Getting Started with Vernier

Biology and Environmental Science Essentials: Getting Started with Vernier (56:08)

Specifications

  • Range: 0 to 20 mg/L, 0 to 300%
  • Accuracy:
    • mg/L
      • ±0.2 mg/L below 10 mg/L
      • ±0.4 mg/L above 10 mg/L
    • %
      • ±2% below 100%
      • ±5% above 100%
  • Response Time: 90% of final reading in 40 seconds
  • Temperature Range: automatic from 0 to 50°C
  • Pressure Range: automatic from 228 mmHg to 1519 mmHg
  • Minimum sample flow: none required

Experiments

Middle School (1 experiments)

ExperimentLab Book
Primary ProductivityInvestigating Environmental Science through Inquiry

High School (15 experiments)

ExperimentLab Book
Biochemical Oxygen DemandAgricultural Science with Vernier
Watershed TestingAgricultural Science with Vernier
Interdependence of Plants and AnimalsAgricultural Science with Vernier
Dissolved Oxygen in WaterAdvanced Biology with Vernier
Primary ProductivityAdvanced Biology with Vernier
Investigating Dissolved OxygenInvestigating Biology through Inquiry
Investigating Primary ProductivityInvestigating Biology through Inquiry
Water MonitoringInvestigating Biology through Inquiry
Interdependence of Plants and AnimalsBiology with Vernier
Aerobic RespirationBiology with Vernier
Dissolved Oxygen in WaterBiology with Vernier
Watershed TestingBiology with Vernier
Physical Profile of a LakeBiology with Vernier
Primary ProductivityBiology with Vernier
Primary ProductivityInvestigating Environmental Science through Inquiry

College (15 experiments)

ExperimentLab Book
Biochemical Oxygen DemandAgricultural Science with Vernier
Watershed TestingAgricultural Science with Vernier
Interdependence of Plants and AnimalsAgricultural Science with Vernier
Dissolved Oxygen in WaterAdvanced Biology with Vernier
Primary ProductivityAdvanced Biology with Vernier
Investigating Dissolved OxygenInvestigating Biology through Inquiry
Investigating Primary ProductivityInvestigating Biology through Inquiry
Water MonitoringInvestigating Biology through Inquiry
Interdependence of Plants and AnimalsBiology with Vernier
Aerobic RespirationBiology with Vernier
Dissolved Oxygen in WaterBiology with Vernier
Watershed TestingBiology with Vernier
Physical Profile of a LakeBiology with Vernier
Primary ProductivityBiology with Vernier
Primary ProductivityInvestigating Environmental Science through Inquiry

Requirements

Choose a platform below to see its compatibility requirements.

LabQuest

InterfaceLabQuest App
LabQuest 3Full support
LabQuest 2Full support 1
LabQuestIncompatible

Compatibility Notes

  1. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter (discontinued) when used with some older LabQuest 2 models.

Computers

Software
InterfaceGraphical AnalysisGraphical Analysis (Web App)
No interface requiredFull supportFull support
LabQuest 3Full support 1Incompatible
LabQuest 2Full support 1 2Incompatible

Compatibility Notes

  1. Connect this sensor directly to a computer or Chromebook via a USB or wireless Bluetooth® connection for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 or LabQuest 3 when the LabQuest is connected via Wireless Data Sharing.
  2. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter (discontinued) when used with some older LabQuest 2 models.

Chromebook

Software
InterfaceGraphical Analysis (Web App)
No interface requiredFull support

iOS

Software
InterfaceGraphical AnalysisGraphical Analysis GW
No interface requiredFull supportPartial support 1
LabQuest 3Full support 2 3Full support 2 3
LabQuest 2Full support 2 3 4Full support 2 3 4

Compatibility Notes

  1. Data can be collected using the sensor’s default calibration only.
  2. Connect this sensor directly to a supported mobile device via a wireless Bluetooth® connection for best results.
  3. iOS and Android™ devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
  4. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter (discontinued) when used with some older LabQuest 2 models.

Android

Software
InterfaceGraphical AnalysisGraphical Analysis GW
No interface requiredFull supportIncompatible
LabQuest 3Full support 1 2Full support 1
LabQuest 2Full support 1 2 3Full support 1 3

Compatibility Notes

  1. iOS and Android™ devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
  2. Connect this sensor directly to a supported mobile device via a wireless Bluetooth® connection for best results.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter (discontinued) when used with some older LabQuest 2 models.

Python

Software
InterfacePython
No interface requiredFull support

Javascript

Software
InterfaceJavascript
No interface requiredFull support 1

Compatibility Notes

  1. A wireless Bluetooth® connection can be made with Go Direct sensors on any platform running a browser with WebBluetooth support. However, only a few operating systems have been tested and testing has been limited.

Arduino

Software
InterfaceArduino
Arduino UNO R4 WiFiFull support

LabVIEW

Software
InterfaceNI LabVIEW
No interface requiredFull support

What's Included

  • Go Direct® Optical Dissolved Oxygen Probe
  • Micro USB Cable
More Information
Manufacturer Vernier
Write Your Own Review
You're reviewing:Vernier - Go Direct® Optical Dissolved Oxygen Probe